Cooling

Cooling Built for AI Density

Cooling Built for AI Density

Cooling Built for AI Density

Liquid cooling systems that remove heat where AI hardware produces it — so your GPUs run at full performance, not throttled by temperature.

Liquid cooling systems that remove heat where AI hardware produces it — so your GPUs run at full performance, not throttled by temperature.

Liquid cooling systems that remove heat where AI hardware produces it — so your GPUs run at full performance, not throttled by temperature.

Beyond air cooling

AI racks have outgrown air

AI racks have outgrown air

AI racks have outgrown air

Today’s GPU servers pack more heat into each rack than fans and raised floors were designed to move. When cooling falls behind, hardware throttles and capacity sits unused.

Today’s GPU servers pack more heat into each rack than fans and raised floors were designed to move. When cooling falls behind, hardware throttles and capacity sits unused.

Today’s GPU servers pack more heat into each rack than fans and raised floors were designed to move. When cooling falls behind, hardware throttles and capacity sits unused.

Liquid carries heat away far more efficiently than air. ASpeed AI Power liquid cooling systems let AI racks run at the densities they were built for.

Liquid carries heat away far more efficiently than air. ASpeed AI Power liquid cooling systems let AI racks run at the densities they were built for.

Liquid carries heat away far more efficiently than air. ASpeed AI Power liquid cooling systems let AI racks run at the densities they were built for.

Why liquid cooling

More compute in the same footprint

More compute in the same footprint

More compute in the same footprint

Higher rack density

Support more compute in the same footprint.

Full performance

Keep GPUs below throttling temperatures under sustained load.

Lower cooling energy

Use less power for cooling than equivalent air systems, leaving more for compute.

Future-ready

Prepare your facility for next-generation hardware that requires liquid cooling.

CDU lineup

Coolant distribution units from 1,350 kW to 2,300 kW

Coolant distribution units from 1,350 kW to 2,300 kW

Coolant distribution units from 1,350 kW to 2,300 kW

Choose a cooling capacity to see full specifications. Every unit uses dual variable-frequency pumps, PG25 coolant, 480V three-phase power, and Modbus RTU / SNMP v3 monitoring.

Choose a cooling capacity to see full specifications. Every unit uses dual variable-frequency pumps, PG25 coolant, 480V three-phase power, and Modbus RTU / SNMP v3 monitoring.

Choose a cooling capacity to see full specifications. Every unit uses dual variable-frequency pumps, PG25 coolant, 480V three-phase power, and Modbus RTU / SNMP v3 monitoring.

Capacity

1,350 kW

Capacity

1,800 kW

Capacity

2,300 kW

Coolant distribution unit

ASpeed AI Power 1,350 kW CDU

Request this unit

Cooling capacity

1,350 kW

Primary flow

1,833 LPM

Max power draw

32.5 kW

Operating weight

2,595 kg

Cooling capacity

1,350 kW @ 4°C ATD

Dimensions (W × D × H)

1200 × 1800 × 2100 mm

Coolant

PG25

Primary flow

484.3 GPM / 1,833 LPM

Secondary flow

475.5 GPM / 1,800 LPM

Primary pressure drop

≤ 13 PSI / 0.9 bar

Secondary pressure

≥ 36.3 PSI / 2.5 bar

Primary inlet / outlet

35°C / 46°C

Secondary inlet / outlet

50.3°C / 39°C

Primary filter

500 μm

Secondary filter

50 μm (25 μm optional)

Pumps

Dual, variable frequency

Flow range

10–100%

Max power draw

32.5 kW

Power supply

3-phase AC 480V ±10%, 50/60 Hz

Design / test pressure

116 / 145 PSI (8 / 10 bar)

External pipe connection

5” clamp

Fill port

UQD04 plug

Power connection

2 × heavy-duty connectors

Communications

2 × RS485 + 2 × RJ45

Protocols

Modbus RTU, SNMP v3

Noise

85 dB(A)

Shipping / operating weight

2,460 / 2,595 kg

Operating environment

0–60°C, 5–95% RH

Storage environment

−40–85°C, 5–95% RH

Finish

Black (RAL 9005)

Specifications may vary by configuration. Contact us for full datasheets, lead times, and pricing.

Certifications and compliance

Built to recognized cooling, pressure and electronics standards

Built to recognized cooling, pressure and electronics standards

Built to recognized cooling, pressure and electronics standards

Liquid cooling

UL 4501

Safety and leak integrity

Liquid cooling

UL 60335-2-40

Electrical safety for coolant distribution equipment

Liquid cooling

ASME Section VIII

Pressure vessels

Electronics

FCC Part 15 Class A

Electromagnetic compatibility

Electronics

UL 62368-1

Safety of control and communications electronics

Certifications vary by model and configuration. Certificates and listing numbers are available on request.

How it works

From rack density to commissioning

From rack density to commissioning

From rack density to commissioning

01

Share requirements

Rack density, hardware, facility water, and timeline.

01

02

Get recommendations

The right CDU capacity with pricing and lead times.

02

03

Delivery and startup

Delivery, installation, and commissioning through our service network.

03

04

Stay connected

Your ASpeed AI Power contact stays with the project through commissioning.

04

Cooling a new AI build?

Pair it with ASpeed AI Power natural gas and diesel generators and 800V rack power sized for the same densities.

Plan your cooling

Plan your cooling

Plan your cooling

Tell us your rack densities and facility details. We’ll recommend the right CDU.

Tell us your rack densities and facility details. We’ll recommend the right CDU.

Tell us your rack densities and facility details. We’ll recommend the right CDU.

Request a Quote