Cooling
Beyond air cooling
Why liquid cooling
Higher rack density
Support more compute in the same footprint.
Full performance
Keep GPUs below throttling temperatures under sustained load.
Lower cooling energy
Use less power for cooling than equivalent air systems, leaving more for compute.
Future-ready
Prepare your facility for next-generation hardware that requires liquid cooling.
CDU lineup
Capacity
1,350 kW
Capacity
1,800 kW
Capacity
2,300 kW
Coolant distribution unit
ASpeed AI Power 1,350 kW CDU
Request this unit
Cooling capacity
1,350 kW
Primary flow
1,833 LPM
Max power draw
32.5 kW
Operating weight
2,595 kg
Cooling capacity
1,350 kW @ 4°C ATD
Dimensions (W × D × H)
1200 × 1800 × 2100 mm
Coolant
PG25
Primary flow
484.3 GPM / 1,833 LPM
Secondary flow
475.5 GPM / 1,800 LPM
Primary pressure drop
≤ 13 PSI / 0.9 bar
Secondary pressure
≥ 36.3 PSI / 2.5 bar
Primary inlet / outlet
35°C / 46°C
Secondary inlet / outlet
50.3°C / 39°C
Primary filter
500 μm
Secondary filter
50 μm (25 μm optional)
Pumps
Dual, variable frequency
Flow range
10–100%
Max power draw
32.5 kW
Power supply
3-phase AC 480V ±10%, 50/60 Hz
Design / test pressure
116 / 145 PSI (8 / 10 bar)
External pipe connection
5” clamp
Fill port
UQD04 plug
Power connection
2 × heavy-duty connectors
Communications
2 × RS485 + 2 × RJ45
Protocols
Modbus RTU, SNMP v3
Noise
85 dB(A)
Shipping / operating weight
2,460 / 2,595 kg
Operating environment
0–60°C, 5–95% RH
Storage environment
−40–85°C, 5–95% RH
Finish
Black (RAL 9005)
Specifications may vary by configuration. Contact us for full datasheets, lead times, and pricing.
Certifications and compliance
Liquid cooling
UL 4501
Safety and leak integrity
Liquid cooling
UL 60335-2-40
Electrical safety for coolant distribution equipment
Liquid cooling
ASME Section VIII
Pressure vessels
Electronics
FCC Part 15 Class A
Electromagnetic compatibility
Electronics
UL 62368-1
Safety of control and communications electronics
Certifications vary by model and configuration. Certificates and listing numbers are available on request.
How it works
01
Share requirements
Rack density, hardware, facility water, and timeline.
02
Get recommendations
The right CDU capacity with pricing and lead times.
03
Delivery and startup
Delivery, installation, and commissioning through our service network.
04
Stay connected
Your ASpeed AI Power contact stays with the project through commissioning.
Cooling a new AI build?
Pair it with ASpeed AI Power natural gas and diesel generators and 800V rack power sized for the same densities.